Updated Design Requirements as of 1/25/2004 @ 10:26am

16.810 students,

We announce two design requirement changes for your second version. The
first is to improve the testing accuracy, and the second is to conform
to the actual testing method.

[1] Holes for fixed boundary condition (lower two holes)
- Diameter: 0.380"
- Cutting quality: 5 (The cutting quality of these two holes must be 5,
regardless of your cutting quality requirement. Other surfaces must
comply with the constraint of your requirement sheet.)

[2] Natural frequency requirement
Conduct a FEA with no boundary conditions. The new natural frequency
requirement for each team is following:

Team 1: 337.2 Hz
Team 2: 463.6 Hz
Team 3: 505.7 Hz
Team 4: 421.5 Hz
Team 5: 505.7 Hz
Team 6: 547.9 Hz
Team 7: 590.0 Hz
Team 8: 632.2 Hz
Team 9: 421.5 Hz