Use block Jacobi preconditioning, each block is (approximately) solved with its own SLES object.

Options Database Keys

-pc_bjacobi_truelocal -Activates PCBJacobiSetUseTrueLocal()

Notes: Each processor can have one or more blocks, but a block cannot be shared by more than one processor. Defaults to one block per processor.

To set options on the solvers for each block append -sub_ to all the SLES, KSP, and PC options database keys. For example, -sub_pc_type ilu -sub_pc_ilu_levels 1 -sub_ksp_type preonly

To set the options on the solvers seperate for each block call PCBJacobiGetSubSLES() and set the options directly on the resulting SLES object (you can access its KSP and PC with SLESGetKSP() and SLESGetPC())

See Also

PCCreate(), PCSetType(), PCType (for list of available types), PC,
PCASM, PCBJacobiSetUseTrueLocal(), PCBJacobiGetSubSLES(), PCBJacobiSetTotalBlocks(), PCBJacobiSetLocalBlocks(), PCSetModifySubmatrices()

Level:beginner
Location:
src/sles/pc/impls/bjacobi/bjacobi.c
Index of all PC routines
Table of Contents for all manual pages
Index of all manual pages

Examples

src/sles/examples/tutorials/ex7.c.html