#!/bin/sh # run from directory where this script is cd `echo $0 | sed 's/\(.*\)\/.*/\1/'` # extract pathname EXAMPLE_DIR=`pwd` # check whether echo has the -e option if test "`echo -e`" = "-e" ; then ECHO=echo ; else ECHO="echo -e" ; fi $ECHO $ECHO "$EXAMPLE_DIR : starting" $ECHO $ECHO "This example shows how to use cp.x to calculate Wannier functions and" $ECHO "to perform dynamics with an external electric field." # set the needed environment variables . ../../../environment_variables # required executables and pseudopotentials BIN_LIST="cp.x" PSEUDO_LIST="H_US.van O_US.van" $ECHO $ECHO " executables directory: $BIN_DIR" $ECHO " pseudo directory: $PSEUDO_DIR" $ECHO " temporary directory: $TMP_DIR" $ECHO $ECHO " checking that needed directories and files exist...\c" # check for directories for DIR in "$BIN_DIR" "$PSEUDO_DIR" ; do if test ! -d $DIR ; then $ECHO $ECHO "ERROR: $DIR not existent or not a directory" $ECHO "Aborting" exit 1 fi done for DIR in "$TMP_DIR" "$EXAMPLE_DIR/results" ; do if test ! -d $DIR ; then mkdir $DIR fi done cd $EXAMPLE_DIR/results # check for executables for FILE in $BIN_LIST ; do if test ! -x $BIN_DIR/$FILE ; then $ECHO $ECHO "ERROR: $BIN_DIR/$FILE not existent or not executable" $ECHO "Aborting" exit 1 fi done # check for pseudopotentials for FILE in $PSEUDO_LIST ; do if test ! -r $PSEUDO_DIR/$FILE ; then $ECHO $ECHO "Downloading $FILE to $PSEUDO_DIR...\c" $WGET $PSEUDO_DIR/$FILE $NETWORK_PSEUDO/$FILE 2> /dev/null fi if test $? != 0; then $ECHO $ECHO "ERROR: $PSEUDO_DIR/$FILE not existent or not readable" $ECHO "Aborting" exit 1 fi done $ECHO " done" # how to run executables CP_COMMAND="$PARA_PREFIX $BIN_DIR/cp.x $PARA_POSTFIX" $ECHO $ECHO " running cp.x as: $CP_COMMAND" $ECHO # clean TMP_DIR $ECHO " cleaning $TMP_DIR...\c" rm -rf $TMP_DIR/cp* $ECHO " done" cat > h2o.wannier.in << EOF &CONTROL calculation = "cp-wf", restart_mode = "from_scratch", nstep = 100, iprint = 100, isave = 100, dt = 4.D0, etot_conv_thr = 1.D-16, ekin_conv_thr = 1.D-16, prefix = "h2o_mol", pseudo_dir = "$PSEUDO_DIR/", outdir = "$TMP_DIR/", / &SYSTEM ibrav = 1, celldm(1) = 20.0, nat = 3, ntyp = 2, ecutwfc = 25.D0, nr1b = 10, nr2b = 10, nr3b = 10, / &ELECTRONS emass = 350.D0, emass_cutoff = 3.D0, ortho_eps = 5.D-8, ortho_max = 250, electron_dynamics = "damp", electron_damping = 0.15, / &IONS ion_dynamics = "none", / &WANNIER adapt = .true., nsteps = 10, / ATOMIC_SPECIES O 16.D0 O_US.van H 2.D0 H_US.van ATOMIC_POSITIONS (bohr) O 10.0000 10.0000 10.000 H 11.7325 9.6757 10.000 H 9.6757 11.7325 10.000 EOF $ECHO " running the Wannier functions calculation...\c" $CP_COMMAND < h2o.wannier.in > h2o.wannier.out check_failure $? $ECHO " Wannier functions spreads...\c">> h2o.wannier.out $ECHO "">> h2o.wannier.out tail -4 $TMP_DIR/h2o_mol.spr >> h2o.wannier.out $ECHO " Wannier functions centers...\c">> h2o.wannier.out $ECHO "">> h2o.wannier.out tail -4 $TMP_DIR/h2o_mol.wfc >> h2o.wannier.out $ECHO " done" # calculation with an electric field cat > h2o.efield.in << EOF &CONTROL calculation = "cp-wf", restart_mode = "reset_counters", ndw = 51 nstep = 200, iprint = 100, isave = 100, dt = 6.D0, prefix = "h2o_mol", pseudo_dir = "$PSEUDO_DIR/", outdir = "$TMP_DIR/", / &SYSTEM ibrav = 1, celldm(1) = 20.0, nat = 3, ntyp = 2, ecutwfc = 25.D0, nr1b = 10, nr2b = 10, nr3b = 10, / &ELECTRONS emass = 350.D0, emass_cutoff = 3.D0, ortho_eps = 5.D-8, ortho_max = 250, electron_dynamics = "verlet", / &IONS ion_dynamics = "verlet", / &WANNIER wf_efield = .TRUE., wf_switch = .TRUE., sw_len = 100, efz1 = 0.5D-2, / ATOMIC_SPECIES O 16.D0 O_US.van H 2.D0 H_US.van ATOMIC_POSITIONS (bohr) O 10.0000 10.0000 10.000 H 11.7325 9.6757 10.000 H 9.6757 11.7325 10.000 EOF $ECHO " running the calculation with electric field...\c" $CP_COMMAND < h2o.efield.in > h2o.efield.out check_failure $? $ECHO $ECHO "$EXAMPLE_DIR: done"