The complete cooling block assembly consists of a ducted copper block, a rubber gasket, and an aluminum back. The rubber gasket was later modified to cover the entire back panel, once it was dicovered that an electrolytic reaction was occuring between the copper and aluminum components. A brief analysis revealed that this change would not significantly reduce the heat transfer rate.