Click here for photo sources and credits

 

Electro-Chemical Potential (ECP) Loop

Irradiated in Summer 2005

  • Evaluated the electrochemical difference between Zircaloy (BWR fuel cladding) and Inconel under simulated BWR conditions (1500#, 550oF).
  • Fourth stage of corrosion experiments using the Shadow Corrosion Test Rig.