*cf_GEV_test
*integration test control file

dr_win -5.e-6  5.e-6
pc_mode multitone
pc_period 1
ion_smooth true
mbd_anchor sbd
samplers 4 abcdefgh ijklmnop qrstuvwx yzABCDEF
ref_freq 6000.0
weak_channel 0.2

*==========================================================
* Set tone mask for n*100 MHz and 3090 MHz
*==========================================================
pc_tonemask cdejnprwBC 2 16 16 1 16 16 16 2 16 16

*default ionosphere search window
ion_npts 45
ion_win  -88.0 88.0

*GE baseline ionosphere search window
if baseline GE
    ion_npts 11
    ion_win  -20.0 20.0

if station G
    sampler_delay_x  240  560  560  560
    sampler_delay_y  240  560  560  560

if station E
    sampler_delay_x 935 935 935 935
    sampler_delay_y 935 935 935 935

if station V
    sampler_delay_x  958  958  958  958
    sampler_delay_y  958  958  958  958